91尤物手机在线观看|欧美日韩国产在线观看网站|激情五月婷婷中文|伊人一区在线观看

<sup id="qlgan"><thead id="qlgan"><pre id="qlgan"></pre></thead></sup>
<ol id="qlgan"><nobr id="qlgan"><kbd id="qlgan"></kbd></nobr></ol>
  • <sup id="qlgan"></sup>
      <acronym id="qlgan"><dfn id="qlgan"><kbd id="qlgan"></kbd></dfn></acronym>

      產(chǎn)品中心

      人鋅指蛋白746(ZNF746)酶聯(lián)免疫吸附檢測試劑盒
      ELK8990
      規(guī)格: 價格:
      48T ¥1960.00
      96T ¥2800.00

      Overview 文獻

      Product name: Human ZNF746(Zinc finger protein 746) ELISA Kit
      Reactivity: Human
      Alternative Names: FLJ31413; zinc finger protein 746; ZNF746
      Assay Type: Sandwich
      Sensitivity: 6.5 pg/mL
      Standard: 1000 pg/mL
      Detection Range: 15.63-1000 pg/mL
      Sample Type: Serum, plasma, tissue homogenates and other biological fluids.
      Assay Length: 3.5h
      Research Area: Neuro science
      Uniprot ID: Q6NUN9
      Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human ZNF746. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human ZNF746. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human ZNF746, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human ZNF746 in the samples is then determined by comparing the OD of the samples to the standard curve.

      標準曲線

      Concentration (pg/mL) OD Corrected OD
      1000.00 2.258 2.172
      500.00 1.699 1.613
      250.00 1.147 1.061
      125.00 0.834 0.748
      62.50 0.597 0.511
      31.25 0.372 0.286
      15.63 0.216 0.130
      0.00 0.086 0.000

      精密度

      Intra-assay Precision (Precision within an assay):CV%<8%

      Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

      Inter-assay Precision (Precision between assays):CV%<10%

      Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

      回收率

      Matrices listed below were spiked with certain level of recombinant ZNF746 and the recovery rates were calculated by comparing the measured value to the expected amount of ZNF746 in samples.
      Matrix Recovery range Average
      serum(n=5) 86-99% 92%
      EDTA plasma(n=5) 86-99% 92%
      Heparin plasma(n=5) 79-93% 86%

      線性

      The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ZNF746 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
      Matrix 1:2 1:4 1:8 1:16
      serum(n=5) 85-97% 87-96% 82-95% 92-105%
      EDTA plasma(n=5) 90-99% 95-106% 87-101% 85-97%
      Heparin plasma(n=5) 87-96% 82-95% 92-105% 78-102%
      關閉

      在線咨詢

      Online consultation

      • 在線咨詢
      • 技術支持

      關注微信公眾號

      微信掃一掃立即咨詢

      微信掃一掃立即咨詢

      關閉