      Overview

      Product name: EasyStep Human TRF(Transferrin) ELISA Kit
      Reactivity: Human
      Alternative Names: TF; Siderophilin; Serotransferrin; Beta-1 metal-binding globulin
      Assay Type: Sandwich
      Sensitivity: 11.9 ng/mL
      Standard: 1000 ng/mL
      Detection Range: 15.63-1000 ng/mL
      Sample Type: Serum, plasma
      Assay Length: 1.5h
      Research Area: Tumor immunity;Infection immunity;Immune molecule;
      Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human TRF, and the Human TRF standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human TRF. After TMB substrate solution is added, only those wells that contain Human TRF and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human TRF in the samples is then determined by comparing the OD of the samples to the standard curve.

      標(biāo)準(zhǔn)曲線

      Concentration (ng/mL) OD Corrected OD
      1000.00 1.961 1.859
      500.00 1.436 1.334
      250.00 1.037 0.935
      125.00 0.682 0.580
      62.50 0.428 0.326
      31.25 0.362 0.260
      15.63 0.212 0.110
      0.00 0.102 0.000

      精密度

      Intra-assay Precision (Precision within an assay):CV%<8%

      Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

      Inter-assay Precision (Precision between assays):CV%<10%

      Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

      回收率

      Matrices listed below were spiked with certain level of recombinant TRF and the recovery rates were calculated by comparing the measured value to the expected amount of TRF in samples.
      Matrix Recovery range Average
      serum(n=5) 82-95% 88%
      EDTA plasma(n=5) 80-95% 87%
      Heparin plasma(n=5) 86-99% 92%

      線性

      The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TRF and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
      Matrix 1:2 1:4 1:8 1:16
      serum(n=5) 83-97% 92-103% 86-97% 93-101%
      EDTA plasma(n=5) 86-101% 86-101% 87-96% 92-105%
      Heparin plasma(n=5) 79-91% 89-103% 82-95% 86-99%