91尤物手机在线观看|欧美日韩国产在线观看网站|激情五月婷婷中文|伊人一区在线观看

<sup id="qlgan"><thead id="qlgan"><pre id="qlgan"></pre></thead></sup>
<ol id="qlgan"><nobr id="qlgan"><kbd id="qlgan"></kbd></nobr></ol>
  • <sup id="qlgan"></sup>
      <acronym id="qlgan"><dfn id="qlgan"><kbd id="qlgan"></kbd></dfn></acronym>

      產(chǎn)品中心

      一步法人胱抑素C(Cys-C)酶聯(lián)免疫吸附檢測試劑盒
      ELK005ES
      規(guī)格: 價(jià)格:
      64T ¥2240.00
      112T ¥3200.00

      Overview

      Product name: EasyStep Human Cys-C(CystatinC) ELISA Kit
      Reactivity: Human
      Alternative Names: CST3; Cystatin 3; ARMD11; Post-Gamma-Globulin
      Assay Type: Sandwich
      Sensitivity: 25 pg/mL
      Standard: 5000 pg/mL
      Detection Range: 78.1-5000 pg/mL
      Sample Type: Serum, plasma
      Assay Length: 1.5h
      Research Area: Tags & Cell Markers;Cell Biology;Stem Cells;Cardiovascular
      Uniprot ID: P01034
      Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human Cys-C, and the Human Cys-C standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human Cys-C. After TMB substrate solution is added, only those wells that contain Human Cys-C and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human Cys-C in the samples is then determined by comparing the OD of the samples to the standard curve.

      標(biāo)準(zhǔn)曲線

      Concentration (pg/mL) OD Corrected OD
      5000.00 2.781 2.716
      2500.00 1.701 1.637
      1250.00 0.906 0.842
      625.00 0.508 0.443
      312.50 0.319 0.254
      156.25 0.177 0.113
      78.13 0.120 0.056
      0.00 0.064 0.000

      精密度

      Intra-assay Precision (Precision within an assay):CV%<8%

      Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

      Inter-assay Precision (Precision between assays):CV%<10%

      Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

      回收率

      Matrices listed below were spiked with certain level of recombinant Cys-C and the recovery rates were calculated by comparing the measured value to the expected amount of Cys-C in samples.
      Matrix Recovery range Average
      serum(n=5) 88-99% 94%
      EDTA plasma(n=5) 102-110% 104%
      Heparin plasma(n=5) 98-104% 101%

      線性

      The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cys-C and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
      Matrix 1:2 1:4 1:8 1:16
      serum(n=5) 93-106% 88-102% 85-101% 96-107%
      EDTA plasma(n=5) 90-103% 94-108% 90-106% 98-105%
      Heparin plasma(n=5) 91-100% 98-107% 92-108% 93-102%

      產(chǎn)品成分表

      關(guān)閉

      在線咨詢

      Online consultation

      • 在線咨詢
      • 技術(shù)支持

      關(guān)注微信公眾號(hào)

      微信掃一掃立即咨詢

      微信掃一掃立即咨詢

      關(guān)閉